Chilled-water pipework where pipe freezing or hot tapping can be used

Pipe Freezing & Hot Tapping in Abu Dhabi

Modify chilled-water pipework without draining the whole system

Draining a large chilled-water system means lost treated water, refilling, venting, re-dosing and a long shutdown. Pipe freezing and hot tapping are two ways to avoid that when a valve needs replacing or a new connection needs adding.

Buraq Electromechanical Works assesses each job in Abu Dhabi for suitability, agrees a method statement with the client, and carries out the work with the rest of the system kept in service.

What is pipe freezing?

Pipe freezing creates a temporary ice plug inside a pipe. Freeze jackets are clamped around the pipe on either side of the work point and cooled until the water inside freezes solid, isolating that short section. The valve, strainer or fitting can then be replaced while the rest of the system stays full. When the work is finished, the plugs thaw and the line is returned to service.

When pipe freezing is used

What is hot tapping?

Hot tapping adds a new branch connection to a pipe while it stays live and pressurised. A fitting is attached to the pipe, a valve is mounted on it, and a tapping machine cuts through the pipe wall through the open valve. The cutter is withdrawn, the valve is closed, and the new branch can be connected — without shutting down the main line.

Pipe freezing vs hot tapping

Pipe freezingHot tapping
PurposeIsolate a section for repair or replacementAdd a new branch connection
System stateFlow stopped in the section being frozenLine stays live and pressurised
Typical useValve, strainer or fitting replacementNew connections for extensions and fit-outs
Key limitsPipe size, material, fluid and flow conditionsPipe material, wall condition, size and pressure

Suitability and safety

Neither method suits every pipe. Before approving the work we check:

The method statement, risk assessment and the client’s permit to work are agreed before work starts.

Our process

  1. Site survey and suitability check
  2. Method statement, risk assessment and permit
  3. Stop pumps or flow in the affected section where required
  4. Freeze or tap, with continuous monitoring
  5. Carry out the replacement or connection
  6. Thaw, pressure-test and return the line to service

Related services

Pipe freezing is most often used for chilled-water valve replacement. Hot tapping is common in HVAC fit-out works where new tenant connections are needed. See also chilled-water and hot-water systems.

How long does a pipe freeze take?

Freeze time depends on pipe size, material and the fluid. Small pipes can freeze in well under an hour, while large-diameter pipes take longer. The plug is held for as long as the work requires.

Does freezing damage the pipe?

When carried out correctly on a suitable pipe, freezing does not damage it. That is why material, wall condition and fluid are checked first.

Can glycol systems be frozen?

It depends on the glycol concentration. Higher concentrations may not form a reliable plug, so other isolation methods may be needed.

Does hot tapping require a shutdown?

No. Hot tapping is done on a live line. Only the new branch is commissioned once it is connected.

Start Your Project

Need to replace a valve or add a connection without draining your system? Send us the pipe size, material and location. Call +971 549982914 or +971 56 515 5334, or email salesauh@buraqllc.com.